Operators of glycol dehydrators in Alberta are periodically required to demonstrate compliance with the benzene emission limits set out in Directive 039 (D39) through audit requests. These requests typically consist of a requirement to provide three years of requested information within 10 business days and require a substantial volume of historical documentation, including DEOS submissions, gas analyses, modelling files, and equipment records for that time period.
The requirements for these audits are generally well defined and consistent from audit to audit. Understanding what will be requested, and maintaining historical records, allows a D39 audit response to be a matter of routine, rather than a substantial effort. The following outlines the typical scope of a D39 audit and the documentation operators should be prepared to provide. For operators without a centralized system, assembling this information can be a time-consuming exercise, often involving multiple departments and file locations.
Audit Requirements:
- Current Compliance Status
Every D39 audit requires confirmation of present-day compliance. Operators must verify that each glycol dehydrator is currently operating within the benzene emission limits set out in the directive.
Where a dehydrator or site is found to be operating above the applicable limits, D39 requires the licensee to:
- Take immediate corrective action to bring the dehydrator(s) and/or site into compliance (for example, reducing glycol circulation rate, decreasing throughput, or suspending operations); and
- Notify the AER without delay at BenzeneD39@aer.ca, detailing the short-term corrective actions taken and the date of implementation.
Corrective action and notification are required immediately upon identifying a non-compliance; there is no grace period. Operators who can determine their current emissions status without first having to run a new calculation are better positioned to identify and respond to non-compliance promptly.
- Three-Year Documentation Requirements
In addition to confirming current compliance, auditors request supporting documentation covering a minimum three-year period for each dehydrator on site. This documentation includes:
- DEOS submissions covering a period of at least three years into the current year.
- Gas analyses for the dehydrator inlet stream, corresponding to each DEOS submission for at least the past three years. These analyses form the basis of the benzene emission estimates and are reviewed alongside the submissions themselves.
- Emissions control equipment details. Where benzene emissions are controlled by a flare, incinerator, or reciprocating engine, the applicable stack height (in metres) must be reported. Where a vapour recovery unit (VRU) is used, the disposition of recovered vapours must be specified (e.g., recycle, injection, or release to atmosphere).
- The emissions determination method and software used, including both input and output reports from the tool applied. Where GRγCalc is used, the corresponding .ddf export files must also be provided.
- Total capture test (TCT) reports, where applicable — all TCT reports applicable to the requested time window for condenser-type systems must be provided.
- Operating status history, including the dates of any shut-in or decommissioning events, and a complete record of operating and not-operating status changes during the audit time window.
- Distance to the nearest public receptor, confirmed as of the current date, together with the receptor type (e.g., private residence, work camp).
Each of these requirements is well defined on its own. The challenge for most operators lies in the aggregate: assembling accurate, current records across multiple dehydrators and multiple years, on short notice.
Common Sources of Delay
In practice, the difficulty in responding to a D39 audit typically stems from the retrieval and compilation of records. When these records are not organized in advance, compiling an audit response can require considerably more time and coordination than the underlying documentation would otherwise demand.
Maintaining dehydrator records within a single, centralized system reduces this risk considerably. Envirosoft’s Dehy Manager is designed to support this approach, consolidating DEOS history, gas analyses, emissions modelling inputs and outputs, control equipment details, and operating status changes for each dehydrator in one location — allowing an audit response to be assembled through record export rather than manual reconstruction.
Summary
A Directive 039 benzene audit is most efficiently managed as an extension of routine compliance practice rather than a discrete, periodic exercise. Operators should maintain current visibility into benzene emissions status, retain copies of historical DEOS submissions, gas analyses, and modelling records organized by dehydrator, and track control equipment details and operating status changes on an ongoing basis.
Maintaining these records consistently allows an audit request to be addressed through existing documentation, minimizing the administrative burden on operations and technical staff.